Metering unit outputs

GE550-2 Energy metering unit outputs for heating/cooling systems

GE550-2 Energy metering unit outputs for heating/cooling systems

SUPPLY UNIT OUTPUTS
Energy metering supply unit outputs, made of brass, for heating and/or cooling systems, complete of:
- Shut-off ball valves with probe holder
- Plastic collars for cabinet installation
- Depending on codes: motorized 2-way zone valve, static balancing valve, inspectable and magnetizable filter with P74M-1 magnet
- Max. working temperature: 110 °C
- Max. working pressure: 16 bar

GE550Y121 - 3/4"
nominal flow rate: 1,5 m3/h
zone valves: NO
balancing valves: NO
filter: YES
unit output length: 264 mm

GE550Y122 - 1"
nominal flow rate: 2,5 m3/h
zone valves: NO
balancing valves: NO
filter: YES
unit output length: 316 mm

GE550Y123 - 3/4"
nominal flow rate: 1,5 m3/h
zone valves: YES
balancing valves: NO
filter: NO
unit output length: 237 mm

GE550Y124 - 3/4"
nominal flow rate: 1,5 m3/h
zone valves: YES
balancing valves: NO
filter: YES
unit output length: 320 mm

GE550Y125 - 1"
nominal flow rate: 2,5 m3/h
zone valves: YES
balancing valves: NO
filter: YES
unit output length: 371 mm

GE550Y135- 1"
nominal flow rate: 2,5 m3/h
zone valves: YES
balancing valves: YES
filter: YES
unit output length: 508 mm

GE550Y136 - 3/4"
nominal flow rate: 1,5 m3/h
zone valves: YES
balancing valves: YES
filter: YES
unit output length: 439 mm

GE550Y137 - 3/4"
nominal flow rate: 1,5 m3/h
zone valves: NO
balancing valves: YES
filter: NO
unit output length: 264 mm

GE550Y138 - 3/4"
nominal flow rate:1,5 m3/h
zone valves: NO
balancing valves: YES
filter: YES
unit output length: 345 mm

GE550Y139 - 1"
nominal flow rate: 2,5 m3/h
zone valves: NO
balancing valves: YES
filter: YES
unit output length: 411 mm

______________________________________________________________

RETURN UNIT OUTPUTS
Energy metering return unit outputs, made of brass, for heating and/or cooling systems, complete of:
- Shut-off ball valves
- Plastic collars for cabinet installation
- Plastic spacer for installation of thermal energy meter
- Max. working temperature: 110 °C (90 °C with plastic spacer)
- Max. working pressure: 16 bar (10 bar with plastic spacer)

GE550Y129 - 3/4"
nominal flow rate: 1,5 m3/h
spacer center distance: 110 mm
unit output length: 254 mm

GE550Y130 - 1"
nominal flow rate: 2,5 m3/h
spacer center distance: 130 mm
unit output length: 300 mm

______________________________________________________________

SUPPLY AND RETURN UNIT OUTPUTS
Energy metering supply and return unit outputs, made of brass, for heating and/or cooling systems, complete of:
- Shut-off ball valves with probe holder
- Plastic collars for cabinet installation
- Inspectable and magnetizable filter with P74M-1 magnet
- Plastic spacer for installation of thermal energy meter
- Depending on codes: motorized 3-way zone valve, static or dynamic balancing valve
- Max. working temperature: 110 °C (90 °C with plastic spacer)
- Max. working pressure: 16 bar (10 bar with plastic spacer)

GE550Y166 - 3/4"
nominal flow rate: 1,5 m3/h
zone valves: YES
balancing valves: NO
spacer center distance: 110 mm
unit output length: 422 mm

GE550Y167 - 1"
nominal flow rate: 2,5 m3/h
zone valves: YES
balancing valves: NO
spacer center distance:130mm
unit output length: 491 mm

GE550Y168 - 3/4"
nominal flow rate: 1,5 m3/h
zone valves: YES
balancing valves: YES, static balancing valve
spacer center distance: 110 mm
unit output length: 453 mm

GE550Y169 - 1"
nominal flow rate: 2,5 m3/h
zone valves: YES
balancing valves: YES, static balancing valve
spacer center distance: 130 mm
unit output length: 491 mm

GE550Y170 - 3/4"
nominal flow rate: 1,5 m3/h
zone valves: YES
balancing valves: YES, dynamic balancing valve
spacer center distance: 110 mm
unit output length: 444 mm

GE550Y171 - 1"
nominal flow rate: 2,5 m3/h
zone valves: YES
balancing valves: YES, dynamic balancing valve
spacer center distance: 130 mm
unit output length: 491 mm

Products

Supply unit outputs and return unit outputs

Code Size BIM(revit) CAD(dxf) Certification
GE550Y121 3/4" - delivery unit 1 0 - -
GE550Y122 1" - delivery unit 1 0 - -
GE550Y123 3/4" - delivery unit 1 0 - -
GE550Y124 3/4" - delivery unit 1 0 - -
GE550Y125 1" - delivery unit 1 0 - -
GE550Y135 1" - delivery unit 1 0 - -
GE550Y136 3/4" - delivery unit 1 0 - -
GE550Y137 3/4" - delivery unit 1 0 - -
GE550Y138 3/4" - delivery unit 1 0 - -
GE550Y139 1" - delivery unit 1 0 - -
GE550Y129 3/4" - return unit 1 0 - -
GE550Y130 1" - return unit 1 0 - -

Supply + return unit outputs

Code Size BIM(revit) CAD(dxf) Certification
GE550Y166 3/4" 1 0 - -
GE550Y167 1" 1 0 - -
GE550Y168 3/4" - static balancing 1 0 - -
GE550Y169 1" - static balancing 1 0 - -
GE550Y170 1" - dynamic balancing 1 0 - -
GE550Y171 1" - dynamic balancing 1 0 - -

Documents

Do you need help with GE550-2?

If you need further information concerning any product, please get in touch with our local Staff

Find your Giacomini consultant

Related products